印刷厂空调解决方案

 工厂车间空调    |      2016-04-06
针对印刷厂的空调解决方案,印刷厂的特点为生产工作场所,印刷厂有少量发热设备,印刷厂内生产人员不会太多。根据印刷厂的特点,空调选型推荐如下:HIMOD E18机型。
This is a solution of A/C for a printing plant. The characteristic of the printing plant is the production of workplace, and there is a small amount of equipment. Production personnel are not too much. According to the characteristics of the space for the printing plant, the selection of model is recommended as HIMOD E18.
经济效益评估:(Economic Evaluation)
  • 该印刷厂需安装空调面积总计600平方米左右,有少量发热设备,对温湿控制及节能有要求,依据实际情况每平米所需制冷量平均按400W计算,总需求的240KW制冷量。
The total area is of about 600 square meters for the printing plant, and there is a small amount of heat source, and it requires the temperature and humidity control and energy saving features. Required cooling capacity per square meter on average calculated based on the actual situation according to 400W, the total demand for cooling capacity is of 240KW.
  • 要满足该项目240KW的制冷量,需使用HIMOD E18机组4套装机。
To meet the cooling capacity of 240KW, this project is needed to use four sets of unit (HIMOD E18).
  • 经济效益对比估算:传统空调满足240KW制冷量的输入功率至少为90KW左右,而HIMOD E18机组4套主机的输入功率合计为58.5KW,主机部分省电35%,全年共计节省电费6万元以上。(按1年运行8个月,1月运行30天,1天运行8小时,用电按1元1度计算)
Comparison of economic benefit estimation: the traditional air-conditioning input power (240KW cooling capacity) is at least about 90KW, and the HIMOD E18 input power per set is of 14.625KW. The energy saving is up to 35%. The annual saving is more than 60400 CNY. (According to 8 months per year, 30 days per month, 8 hours per day of operation, electricity by 1 CNY/1 degree calculation)